Data Center Map

                DataBank - West Twin Cities


                » Index » USA » Minnesota » Minneapolis » DataBank - West Twin Cities

                DataBank - West Twin Cities is located in the area Minneapolis, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 04-05-2017.


                Address:
                DataBank
                7700 France Avenue S.
                55435 Minneapolis
                Minnesota, USA

                » Request quote
                » Visit website

                Click here to find other data centers
                owned and operated by DataBank.


                Profile
                Tenants
                Connectivity
                Request quote
                Office space
                Rack Cabinets
                Dedicated Servers
                Suites
                Footprints
                Virtual Servers
                Cages
                Hosting of individual servers
                Remote Hands

                Profile


                Our WestTwin Cities Data Center is located in the suburb of Edina, MN. The property came to DataBank through the acquisition of VeriSpace in March of 2013. The site houses many prominent local and statewide businesses in the business-friendly location and features on-site security staff 24/7/365. DataBank invested over 5 Million to expand and update the facility in 2013. Newly constructed customer-use offices, conference rooms, lounges, equipment staging and storage were also a part of the retro-fit.

                General Specifications:

                * Top-tier Minneapolis data center facility with available capacity & power
                * South Minneapolis office park setting in Edina, MN
                * 17,000 sq ft of data center space

                Security:

                * 24/7/365 on site security
                * Card access required to gain access to parking and building lobby
                * Biometric hand scanner required for data center entry
                * Annual SSAE 16 & PCI-DSS Audits

                Cameras:

                * Multiple 360 degree cameras with 10x zoom
                * Minimum 90 day tape storage

                UPS & Generator Backup Power:

                * On-site power generation
                * All UPS and Generator deployments provide redundancy

                Utility Power:

                * 5MW of incoming utility power
                * Multiple utility feeds from redundant substations
                * Feeds to building are concrete encased

                HVAC Cooling System:

                * Over 675 Tons cooling capacity
                * Data Center HVAC system includes high-efficiency CRAC/CRAH Units.
                * Entire system is designed with at least N+1 redundancy
                * Liebert Leak Detect System


                DataBank - West Twin Cities Pricing/Quotes


                If you are interested in receiving a quote for DataBank, please try our free quote service.