Data Center Map

                Cogent Minneapolis


                » Index » USA » Minnesota » Minneapolis » Cogent Minneapolis

                Cogent Minneapolis is located in the area Minneapolis, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 26-12-2018.
                This data center is located within 250 Marquette Avenue.

                Address:
                Cogent Communications, Inc.
                250 Marquette Ave
                55401 Minneapolis
                Minnesota, USA

                » Request quote
                » Visit website

                Click here to find other data centers
                owned and operated by Cogent Communications, Inc..


                Profile
                Tenants
                Connectivity
                Request quote
                Office space
                Rack Cabinets
                Dedicated Servers
                Suites
                Footprints
                Virtual Servers
                Cages
                Hosting of individual servers
                Remote Hands

                Profile


                On-Net Products
                . IP Transit
                . Ethernet Transport Services

                Standard Rack Configuration
                . 42U APC Cabinets (Model: AR3100).
                . Power extra (110v/20 amp or 2x 110v/20amp is standard)

                Facilities
                . 11,521 square feet of raised floor data center space
                . 480v 3-phase utility feed - 1600 amps
                . Custom cages available

                Security
                . C*CURE Card-Reader Access Control System
                . 13 card readers total at all essential doors
                . Entrance into actual data center requires HID card swipe and unique pin code for access
                . Four IP cameras in use w/ recording & 24/7 monitoring capabilities to the Cogent NOC, one at main entrance into data center
                . 24/7 building security w/ video camera surveillance
                . Building system access badge required after hours, during weekends and on holidays

                UPS Systems
                . 225kVA UPS Unit (Model: Powerware 9315)
                . 40-battery string for UPS Unit (C&D)

                Generator Systems
                . Caterpillar Diesel Generator, 1500kW
                . 4,000 gallon diesel tank
                . 2,000 Amp RussElectric Automatic Transfer Switch

                HVAC
                . (5) 20-ton Airflow HVAC units with rooftop condensers provide cooling for data center floor.
                . (3) 5-ton Airflow HVAC units with rooftop condensers provide cooling for electrical/power rooms

                Electrical/Fire/Monitoring
                . Fire suppression & detection system consists of heat detectors, smoke heads and a pre-action sprinkler system