                AdNet - DataCity Bucharest


                » Index » Romania » Bucharest » AdNet - DataCity Bucharest

                AdNet - DataCity Bucharest is located in the area Bucharest, Romania, and the colocation data center is carrier neutral. The data center was last updated on 04-07-2017.


                Address:
                BinBox Global Syervices
                Blv. Pipera, Nr.1/VI
                077190 Voluntari
                Ilfov, Romania

                » Request quote
                » Visit website

                Click here to find other data centers
                owned and operated by BinBox Global Syervices.


                Profile
                Gallery
                Tenants
                Connectivity
                Request quote
                Office space
                Rack Cabinets
                Dedicated Servers
                Suites
                Footprints
                Virtual Servers
                Cages
                Hosting of individual servers
                Remote Hands

                Profile


                TIER III DESIGN:
                Availability higher than 99.982%
                Redundant power elements with independent
                circuits paths configured in as 1+1
                Redundant cooling elements with
                independent circuits paths configured in as N+1
                Provides concurrent maintenance

                ENERGY EFFICIENT:
                Optimized IT Equipment arrangement in Cold/Hot Aisle
                Advanced multistep cooling control allow for high efficiency
                Integration of green energy such as photovoltaic and wind turbine
                High performance rectifiers, inverters and accumulators in UPS system
                Targeted PUE - Power usage effectiveness lower than 1.3 for 100% load
                Actual PUE - 1.75 at 20% Load

                IT & TELECOM INFRASTRUCTURE:
                IT infrastructure design for TIER III
                Multipath optical fiber on 3 circuits
                High end border routing equipment Juniper MX series
                Data Center L2 and L3 switching performed by Cisco Nexus
                Complex evolved virtualization platform based on Cisco UCS, HP 3PAR
                storage and VMWare VCenter/Vsphere
                Cluster balancing technology from A10 Networks
                Advanced traffic anomaly detection and cleaning with Arbor System technology
                Complete internal data circuits distribution with Panduit materials

                COOLING:
                Adiabatic & Free cooling - Indoor for IT Containers:
                60 racks with average power of 7 KW arranged in 3 cold aisle with 20 racks each resulting in a total power of 140KW / cold aisle
                24 LCU providing 20KW of cooling arranged in 3 cold aisle resulting in 8 units / row with a capacity of cooling of 160KW (7+1)
                In-line positioning with racks, Cold-Isle/Hot Isle containment with front to back airflow
                Cooling agent: thermic agent with heat transfer properties optimized for whole range of meteorological conditions
                Chiller water cooling - Outdoor:
                3 x 300KW chiller units with Free Cooling mechanism
                "Air-Conditioning" type water cooling - compressors based in 12 steps (4 independent compressors / chiller unit)
                N+1 Redundant compressors, ventilators and other components (according to TIER III standards for cooling)
                Automation system for adjusting electrical energy consumption
                Adiabatic & Free cooling - Indoor for Power containers
                4 units 30KW
                N+1 redundancy type according to TIER III standards for power supply

                POWER & UPS:
                Total installed power 480 kW x 2 with redundancy in 2 lines
                2 automatic back-up diesel generators one for each line
                Accumulators pack - 108 with 100 Ah capacity for each power box
                2 UPS of 40 kVA for chiller pumps
                2 UPS of 20 kVA for interior modules of inline cooling units
                2 heating pumps and 1 ice pillar for extra heat removal before Chillers
                1 wind turbine with 2 KW - providing auxiliary power
                80 x 250W (20 KW) photovoltaic farm - compensating in extra hot summer days

                RACKING & VIRTUALIZATION:
                Racks
                Hardened steel Racks:
                45U racks space proving at least 42U usable IT Equipment
                Depth: 1000mm
                Width: standard 19''
                PDU: for each Rack 2 PDU three-phase power supply of 400V - Maximum power 11 KW redundant/ Rack, each PDU with 24 IEC13 sockets and 6 IEC19 sockets
                Assembling on metallic anti vibration and anti seismic system

                Virtualization system
                Cisco UCS Blade Server System
                5 x Blade server chassis each with 8 blade server units installed
                Installed processing power ~ 1800 VCPU
                Installed memory : 7168 GB
                HP 3PAR 7400 Enterprise Storage Dual controller with 200TB of usable space (250TB installed)
                Storage: even mix of SAS/NL-SAS disk
                Switching: Integrated Cisco switch fabric with extra 32 port 10GB for external connectivity
                VMWare VSphere/VCenter Enterprise plus virtualization system

                SECURITY SYSTEM:
                Complex security system
                Fire detection system
                Smoke detection sensor
                Temperature sensor
                Fire extinguisher cylinders
                Fire detection station
                Exterior fire alarm control panel from fast access from outside
                Dual power source, both from main power supply and UPS
                Access control module
                Emergency fire path - both mechanical and electromagnetic
                Magnetic stripe card access
                Unlimited user access with multiple roles and rights
                Control panel integration with fire detection and extinguisher system - automatic fire path unlocking
                Real time reports and history : access type, users, access path, etc.
                Surveillance system
                HD IP cameras
                NVR recording and monitoring
                Minimum 30 days data storage in

                INFRASTRUCTURE MANAGEMENT:
                Complex monitoring and management software suite integrating all hardware and software components installed in the datacenter infrastructure (power elements, cooling elements, security & surveillance, sensors & monitoring devices)
                Data center components detailed charts and schematics (racks, cooling, power, surveillance, control access, sensors, etc.)
                IT Equipment layout
                Power supply, circuits and distribution
                Chillers, LCU, cooling paths
                Surveillance, access control, firefighting systems
                Humidity, temperature, air quality, flood sensor system
                Renewable energy controllers
                Real time & Historical monitoring for all managed systems
                Statistics, Graphics and Analysis of various parameters
                Friendly graphical web user interface compatible with most modern browsers

                CONNECTIVITY:
                Physical connections (L1):
                3 paths geographically and logically independent underground optical fiber links - 144 optical wires available
                Open Third-party fiber optic interconnection cabinet easily accessible from any underground infrastructure
                Logical connections (L2-L3):
                Data center node is included in main N x 10Gbps metropolitan multi-ring core network of 2K Telecom, providing high capacity resilient communications with most POP or exchange nodes
                Juniper MPLS Switches and Routers provide any type of logical connection (L2 circuits, VPLS, L3 VPN, QinQ, Dark Fiber, TDM transport, etc.)
                External connections (National&Internet)
                2KTelecom is member of public Internet Exchanges: Interlan, Balkan-IX RoNIX, NxData, IBM Data Center, INES Datacenter, Cyberhost Datacenter
                Extra private national interconnection with leading ISP providers improve capacity and latency
                Optimized Balanced Access to Internet is achieved through major world wide Internet Carriers (M247/NTT, Telekom/LEVEL3)








                AdNet - DataCity Bucharest Pricing/Quotes


                If you are interested in receiving a quote for BinBox Global Syervices, please try our free quote service.